Knowledge
Glossary of building management and maintenance
Short explanations of the terms you meet in building management, maintenance plans, condition assessments and inspections.
- Asset
- Balance method
- Bbl (Dutch Building Decree)
- Building element
- Condition assessment
- Condition score
- Corrective maintenance
- Cycle
- Defect
- Extent
- Finding
- Indexation
- Inspection
- Inspection certificate
- Intensity
- Long-term maintenance plan (MJOP)
- NEN 2767
- NEN 3140
- NL-SfB
- Preventive maintenance
- Rebuild value
- Reserve fund
- Safety net (decay)
- Service life
- Severity
- Sustainable maintenance plan (DMJOP)
- Theoretical condition
- Work order
- Asset
- Anything in or on a building that you manage and maintain: a lift, boiler, roof or fire extinguisher. In Klantpunt every asset can be placed on the floor plan, with components, inspections and history.
- Balance method
- A way to calculate the reserve: each year you check whether the reserve fund balance covers the planned spending.
- Bbl (Dutch Building Decree)
- The national rules for building and using buildings under the Dutch Environment Act, since 2024. They include requirements for fire alarm, evacuation alarm and firefighting equipment.
- Building element
- A recognisable part of a building or installation that you assess separately, such as a window frame, a roof covering or an air handling unit. In a condition assessment each element gets a score.
- Condition assessment
- An inspection that records the technical state of building elements, usually per NEN 2767. The result feeds the maintenance plan.
- Condition score
- A number from 1 (excellent) to 6 (very poor) for the technical state of a building element per NEN 2767.
- Corrective maintenance
- Maintenance after a failure or damage. The opposite of preventive maintenance.
- Cycle
- How often a maintenance activity recurs, in years. Painting every 6 years has a cycle of 6.
- Defect
- A deviation from the desired state, such as cracking, corrosion or leakage. A defect has a severity, intensity and extent.
- Extent
- Which part of an element a defect affects, as a percentage. NEN 2767 groups it into five classes.
- Finding
- Something you record during a round or inspection: a defect, damage or report, with location, photo and priority.
- Indexation
- Raising the amounts in a budget each year for price increases, for example 2.5% a year.
- Inspection
- A periodic check that an installation is safe and compliant, often by a designated or certified party.
- Inspection certificate
- Proof from an independent inspection body that an installation complies, as for a required fire alarm system. Valid for a fixed period.
- Intensity
- How far a defect has developed: initial, advanced or final stage. One of the three characteristics in NEN 2767.
- Long-term maintenance plan (MJOP)
- A plan with the maintenance and replacements for the coming years, usually 10 to 30, with costs per year.
- NEN 2767
- The Dutch standard for recording the condition of buildings and installations, with a fixed method and scores from 1 to 6.
- NEN 3140
- The Dutch standard for safe operation and periodic inspection of electrical installations and equipment at work.
- NL-SfB
- A coding system for building elements and installations, such as 27 for roofs and 66 for lifts. Useful to classify assets and costs consistently.
- Preventive maintenance
- Planned maintenance to prevent failures and damage, such as annual boiler servicing.
- Rebuild value
- What it costs to rebuild a building, excluding land. Basis for buildings insurance and for the minimum reserve of a Dutch owners' association without a plan.
- Reserve fund
- Money an owners' association sets aside for future major maintenance. Every Dutch owners' association must have one; for (partly) residential buildings a minimum annual contribution also applies.
- Safety net (decay)
- In NEN 2767, a way to include ageing for parts you cannot assess, based on age relative to service life.
- Service life
- How long an element or installation is expected to last. Basis for the replacement moment in the maintenance plan.
- Severity
- How much a defect matters for the function of an element: minor, serious or critical. One of the three characteristics in NEN 2767.
- Sustainable maintenance plan (DMJOP)
- A maintenance plan that also includes sustainability measures, such as insulation or a heat pump, linked to natural replacement moments.
- Theoretical condition
- The condition you expect from age alone: above 50% of the service life 2, above 75% 3 and above 87.5% 4.
- Work order
- An instruction to a technician or supplier to carry out a job, with description, location and schedule.
See Klantpunt with your own building
In half an hour we show you how it works, using one of your buildings as the example. Afterwards you get a quote that fits.
- A reply within one working day
- Fixed prices, never per user
- We import your existing lists for you
Email us: [email protected]
Rather read first?
The ten-page brochure in your inbox.